with the Vascutek Gelweave Valsalva™ Graft1
The only valve/graft combination to offer:
- A generous PTFE2 sewing ring for ease of suturing
- The first coated valsalva graft for optimal coronary ostia reimplantation
- Ongoing FDA IDE approved reduced anticoagulation clinical trial

Product Specifications
| Valve Size | Catalog Number | Valve Internal Diameter (mm) | Valve Orifice Area with Leaflets in Place (cm2) | Sewing Ring Diameter3 (mm) | Graft Diameter (mm) | Graft Length (cm) |
| 19 | ONXAAP-19 | 17.4 | 2.00 | 27 | 20 | 11 |
| 21 | ONXAAP-21 | 19.4 | 2.53 | 30 | 22 | 11 |
| 23 | ONXAAP-23 | 21.4 | 3.13 | 33 | 24 | 11 |
| 25 | ONXAAP-25 | 23.4 | 3.73 | 34 | 26 | 11 |
| 27/29 | ONXAAP-27/29 | 23.4 | 3.73 | 36 | 26 | 11 |
Surgeon Quotes
“ . . . , the mechanical On-X valve exhibited improved hemodynamics, low TE and thrombosis rates, and low degrees of hemolysis, particularly in the aortic position.” Palatianos, et al.4
“ . . . , these data suggest that in a well-controlled population, anticoagulation at a lower level than that usually recommended would adequately mitigate thrombosis and thromboembolism, with a low incidence of anticoagulant hemorrhage. These data also confirm the excellent hemodynamics of the On-X valve . . . .” Williams, et al.5
“The advantage of using the On-X valve, however, may be its low propensity to thrombogenesis.5 Clinical trials looking at long-term outcomes in patients with the On-X valve receiving low levels of anticoagulation, including patients on aspirin and clopidogrel alone, are currently in progress.” Yezbick, et al.5,6
“ . . . . by using the new conduit [Vascutek Gelweave ValsalvaTM Graft] a valve motion more similar to that of the normal subject group was observed.” DePaulis, et al.7
“ . . . we preferred to use a Valsalva graft [Vascutek Gelweave ValsalvaTM Graft], as we believe it offers a better anatomical restoration of the aortic sinuses, producing a leaflet motion similar to that of normal subjects.” Pitsis, et al.8
References:
- The Vascutek Gelweave ValsalvaTM Graft is a product of Vascutek, a Terumo Company http://www.vascutek.com.
- On-X valve sewing rings are made of PTFE–polytetrafluoroethylene.
- Sewing ring nominal dimensions.
- Palatianos G, Laczkovics A, Simon P, et al. Multicentered European study on the safety and effectiveness of the On-X® Prosthetic Heart Valve: Intermediate follow-up. Ann Thorac Surg 2007;83:40-46
- Williams MA, van Riet S. The On-X heart valve — mid term results in a poorly anticoagulated population. J Heart Valve Dis 2006;15:80-86
- Yezbick AB, Ho JK, Crowley R, et al. Echocardiographic signature of the On-X valve. Echocardiography: J CV Ultrasound Allied Tech 2008;25(9):1016-18
- DePaulis R, De Matteis GM, Nardi P, et al. Analysis of valve motion after the reimplantation type of valve-sparing procedure (David I) with a new aortic root conduit. Ann Thorac Surg 2002;74:53-57
- Pitsis AA, Bougioukas IG, Kelpis TG, et al. Modified (valvsalva graft) aortic root reimplantation for successful repair of pulmonary autograft aneurysm after Ross procedure. Hellenic J Cardiol 2007;48:47-49
The On-X® Ascending Aortic Prosthesis with the Vascutek Gelweave Valsalva™ Graft is FDA approved.
CAUTION: Use of this device in the Prospective Randomized On-X Valve Anticoagulation Clinical Trial (PROACT) is limited by federal law to investigational sites. CAUTION: Federal law restricts this device to sale by or on the order of a physician. Refer to the Instructions for Use that accompany each valve for indications, contraindications, warnings, precautions and possible complications. For further information, visit www.onxlti.com.